134-28 - Building Articulation LAST AMENDED 5/27/2021 Within the Southern Subdistrict, any portion of a #building# that is located at or below a height of 75 feet, and has a #street wall# width greater than 200 feet, as measured parallel to the #street line#, shall provide recesses in accordance with the following requirements: (a) recesses shall be required to extend along at least 25 percent of the #street wall# width that is in excess of 200 feet. No required recess shall have a width of less than 10 feet; (b) such recesses shall have an average depth of at least 10 feet; (c) such recesses may be of varying dimensions and heights, provided that the requirements of this Section are met at each level of the #building#. No articulation shall be required where frontage requirements apply pursuant to paragraph (b)(1) of Section 134-24 (Height and Setback Regulations).